Instructions for the installer
15
5.3 Regulation for natural gas
The hob has been adjusted for natural gas at a pressure of 1.0kPa. To
allow the unit to work back with this type of gas, after it has been adjusted
for LPG, perform the same operations described in paragraph “5.2
Adjustment for LPG”, but refer to the following table for the proper
injectors.
Burner
NG – 1.0 kPa
Nominal gas consumption
(MJ/h)
Injector
(mm)
Auxiliary (1) 4.8 0.98
Semi-rapid (2) 6.0 1.10
Rapid (3) 12.2 1.55
internal (4) 4.8 0.98
Double crown
external (4) 14.0 1.65